MCon Carbo 16-48
- Calculates C-level from the residual oxygen content of a gas or CO2-content from the furnace atmosphere
- Various types of thermocouples, lambda-, O2-probes and other gas sensors e.g. CO, CO2
- C-level correction by foil tests
- Color-TFT-touch-screen display with additional keypad
- Multi-user access with usernames, pass-words and access levels
- Isolated analog inputs
- Current supply 115 or 220V 50/60Hz or 24V
- Optional: Profibus, Modbus and “MESA Legacy” protocols
PRINCIPLE OF OPERATION:
MCON Carbo 48 and 16 is a new and advanced calculator of carburizing processes in heat treatment plants.
Degree of Protection:
IP54 according to IEC 60529Dimensions:
MCon Carbo 1696 x 96 x 111 mm (W x H x D)
MCon Carbo 48
296 x 256 x 118 mm (W x H x D)
Housing made of polystyrene
Power Supply:
AC 85VAC…265VAC, 50-60HzPower Consumption:
15VADisplay:
Color-TFT-touch-screen display, 320 x 240 pix16it, 3,5’ with robust touch-screen
Communication Interface (Optional):
Isolated RS485/422, ProfibusClimate:
Storage: -10…+70 °COperation: 0…+50 °C
5…95 % relative humidity, non-condensing
Analog inputs:
AIN 1:
– Thermocouple, Type “K” or “S”AIN 2:
– L-probe– O2 probe
– CO2-Analyzer
AIN 3:
– CO-AnalyzerAnalog outputs:
AOUT 1:
– Raw O2 probe voltage– Calculated O2 probe mV from L-probe mV
AOUT 2:
C-level: 0…2,0 %C -> 0…20 mA or 0…10 VAOUT 3:
Temperature: 0…1200 °C -> 0…10 VAOUT 4:
mV O2 correctedC-Level Measuring Range:
0…2.0 %CC-Level Measurements:
Sensors for measurement: O2, lambda probes orCO2 analyzer
Fixed or measured CO
Up to 5 Foil test correction points
OUR PRODUCT IN THE INDUSTRY
This unit is for use in a heat treatment industry.