GAS ANALYZER SYSTEM MGAS 5.X

An instrument for measuring the following Gas- Concentrations:
  • Carbon monoxide %CO
  • Carbon dioxide %CO2
  • Hydrogen %H2
  • Methane %CH4
Customizable Gas components are possible. Following components will be calculated:
  • C-Level from CO2, CO, and Temperature or Temperature, CO and mV*
  • Dew point from CO2, H2 and Temperature or Temperature, H2 and mV*
*mV from Lambda probe or 02-Probe

This equipment is qualified to measure furnace atmospheres online with, max. 6 different gas sensors. Eight analogous outputs, eight digital inputs/outputs, and an optional serial interface are possible. The communication with the serial interface can be done with Modbus, TCP Ethernet, or Profibus.

All Analog and Digital inputs/outputs can be configured manually e.g. as Alarm, starting calibration, or switching off-pump. An optional data logging function with USB data transfer and internal memory with 16MB is available. The logging function can work in manual or timer mode. With the delivered Software “MGas Viewer” you can visual, print, export, and administrate your stored data.

The equipment is adjustable by a high-quality foil keyboard with self explainable menu structure in German and English language. Automatic calibration for zero-point and span for all gas components is possible. There is an additional calibration function called “fast calibration” which allows the user to change the displayed gas concentrations manual. Additional it is possible to configure several protection functions, e.g. switching off at high Dew Point or low Process Temperature, to increase the lifetime of the device. The advanced gas transducers represent the latest technological achievement in non-dispersive infrared gas transducers with high accuracy, good long-time stability, and excellent repeatability.

Device construction:

Desktop variant: 450 x 200 x 440 (w x h x d)
Rack variant: U=4, HP=84, D=400mm

Weight:

Approx. 14 kg

Protection type:

IP 20 to IEC 529

Power supply:

230V +4% / -10%, 50-60Hz or
115V ± 10%, 50-60Hz

Power:

Approx. 70W / Slow Fuse 2A in Power switch

Communication

MODBUS
RS232, RS422, RS485
Ethernet over TCP/IP
Profibus

Heat-up time:

Approx. 10 min.

Climate:

Storage: 0…50 °C
Operation: 5…40 °C

Measuring range:

CO: 0…35,0 %
CO2: 0…0,500 %, 0…1,000 %, 0…2,000 %
H2: 0…80,0 %
CH4: 0…5,0 %, 0…10,0 %, 0…20,0 %
°C: 0…1200 °C
C: 0…1,50 %
O2: 0…1300 mV
TP: -30…+30 °C

Measuring gas components:

max. 6

Oxygen probes:

Lambda probe or O2 probe

Additional calculation:

C-Pegel
°C Taupunkt

Measuring method:

NDIR dual-wavelength principle no moving parts

Influence values:

Drift with autocal. : insignificant
Drift without autocal :± 2% FS over 12 months
Linearity error: : < 2% FS
Temperature dependence with autocal : insignificant
Temperature dependence without autocal. : ± 2% FS/10 °K
Druckabhängigkeit:± 0.2% FS/10 mbar
Pressure dependence: Compensated by internal pressure sensor between 800 mbar and 1200 mbar. : zwischen 800 mbar und 1200 mbar.

Gas inputs:

Measurement gas input
Zero gas input
Reference gas input

Pressure:

Maximal pressure: 100 mbar overpressure (ü)
Working pressure: 0 do 50 mbar overpressure (ü)
Gas flow: Approximately 0,4 l/min

Gas outputs:

Gas output 1 , Gas output 1
Sind Druck los an zu schließen

OUR PRODUCT IN THE INDUSTRY

This unit is designed for use in the heat treatment industry