OXYGEN PROBE FOR HEAT TREATMENT SYSTEMS TYPE: KE
- Heating systems
- Industrial processes
- process technology
- Gas analysis
- Heat treatment
The KE oxygen probe is suitable for direct installation in the furnace atmosphere and is maintenance-free. The emf output corresponds to the Nernst voltage. The probe temperature is recorded by a PtRh-Pt thermocouple.
The oxygen probe is suitable for direct connection to all well-known C-level control systems (e.g. MCON Carbo).
The probe delivers a continuous measuring signal and is characterized by a fast response time.
The current one is derived from the Nernst probe voltage and the EMF of the thermocouple.
Calculated carbon content of the furnace atmosphere.
The remaining service life of the probe can easily be determined from the reproducible internal resistance.
Sensing element:
Continuous zirconia tubeMeasuring range:
1 … 10 -28 bar partial pressureresponse time
approx. 1 second.Working temperature:
700 … 1050 ° CThermocouple:
Pt10Rh-Pt type “S”, DIN 43710Protection tube:
Heat-resistant steel or according to customer requirementsNominal length:
600 mm special lengths up to 1200 mmInstallation thread:
1 “GConnection:
Clamping sockets and plugs separated for probe and thermocoupleConnection for air lines:
Reference air and purge airOUR PRODUCT IN THE INDUSTRY
This unit is designed for use in the heat treatment industry